The Storage Management Command Line Interface (SMcli) in interactive mode has complete error checking and will give the user useful feedback during use. = False True What is the new term for channel on a PowerVault MD1000 with a PERC5/e? = Connector Sub-channel Port Field If an administrator password is set on a PowerVault MD3000, configuration change commands can still be issued from the Storage Management Command Line Interface (SMcli). ? True False When replacing the backplane in a PowerVault MD3000, although it is recommended to replace the service tag on the new backplane with the original service tag, the Premium Features will continue to operate normally with the new service tag. True =?? False When using the Storage Management Command Line Interface (SMcli), it is recommended to use the interactive interface rather than the scripted interface. = False True What is the maximum allowable cable length when connecting SAS on the PowerVault MD3000? 6 meters 12 meters 1 meter = 4 meters What common color is the front drive carrier on the PowerVault MD3000? Gold Blue Terracotta = Black In a PowerVault MD3000 with single port controllers, only one Host can be connected. = True False In a PowerVault MD3000 with dual port controllers, each Host will have both of its HBAs cabled to one controller. = False True How many captive screws secure the battery assembly in the RAID Controller Module of the PowerVault MD3000? 3 = 2 0 1 How many hard drives are supported in the PowerVault MD3000 storage enclosure? = 15 14 18 16 In cabling each host to the PowerVault MD3000, each host must have a minimum of two SAS connections to the Storage Array. True = False How many power cables are required to plug-in the two power supplies on the PowerVault MD3000? = 2 1 0 7 Even if a PowerVault MD3000 power supply fails, the enclosed fans will continue to operate on the common fan bus voltage bus. = True False Each PowerVault MD1000 power supply is secured with three thumbscrews. True = False If a power supply/cooling fan module fails in a PowerVault MD3000, which of the following is the most accurate? The fans in the failed module will not continue to operate but the failed module must be left in place. ?? The fans in the failed supply will continue to operate until the module can be replaced The module must be removed, even if a replacement is not available. The fans in the failed supply will come on only if the enclosure temperature reaches the ¡°critical¡± set point. Each PowerVault MD3000 power supply is secured with three thumbscrews. True = False If a PowerVault MD3000 hard drive is accidentally removed while the drive is online how long should the user wait before re-inserting the drive? 5 minutes No waiting is necessary = 30 seconds 10 seconds How many screws secure the front faceplate on a PowerVault MD3000? 10 14 = 16 18 What type of drives are supported in the PowerVault MD3000? Floppy None of those listed IDE = SAS hard drives How many screws must be removed from the EMM/power supply cage when removing the PowerVault MD3000 midplane? 8 6 = 4 16 True/False In a PowerVault MD3000 with dual port controllers, each Host will have both of its HBAs cabled to one controller. == False True True/False Even if a PowerVault MD3000 power supply fails, the enclosed fans will continue to operate on the common fan bus voltage bus. False === True