Dell OpenManage Server Assistant helps users install a server operating system. False = True If a RAID controller is installed in a server when it is booted with the DSA CD, an option will be appear to configure RAID on the system. False = True The DSA CD can be used to install Red Hat Linux on a server. = True False ?RAID Management utilities that provide error statistics logging are: = Linux CLI Dell OpenManage IS Assistant = BIOS Configuration Utility = Dell OpenManage Array Manager RAID 5 combines striping of a RAID 0 with an exclusive OR operation to calculate recovery data. False = True Dell's RAID controllers support the following levels: = 0 = 1 = 50 30 The XEON CPU in the PowerEdge 6800/6850 is different from the XEON MP which is: = Designed to run on more than two CPUs Less on-die cache An upgrade to the older MX technology Designed to run on only one CPU Virtual disks can be created using a Dell PERC 4/di controller. = True False The BMC firmware on a PE850 can be updated via a USB memory key. = True False Data is duplicated at a block level in RAID 1 to create ________ identical drives. 5 = 2 7 3 Which network card is integrated on the PowerEdge 850 system board? Broadcom BCM5704 Intel 82450 Intel 83451E1 = Broadcom 5721J Which RAID controllers are supported on the PowerEdge 830? = PERC4e/DC PERC4/DC = CERC SATA 6ch = PERC4/SC Which memory module is not supported on the PowerEdge 850? 1 GB DDR2 667 MHz unbuffered SDRAM DIMM = 256 MB DDR2 400 MHz unbuffered SDRAM DIMM 512 MB DDR2 533 MHz unbuffered SDRAM DIMM 2 GB DDR2 667 MHz unbuffered SDRAM DIMM Memory must be installed as follows in the PowerEdge 6850: In pairs (single-rank only) Both banks per riser card Every other slot on the riser card = In pairs (ranks must match within the bank) Spare bank and memory mirroring can be enabled at the same time on the PowerEdge 6850. = False True The PowerEdge 6850 has a dedicated slot for an Integrated Fibre Channel Module. False = True The PowerEdge 6800 and PowerEdge 6850 uses a Xeon MP processor. = False True !!! Which of the following expansion slots are available in the PowerEdge 6850? = PCI-e and PCI-x PCI-x only PCI-e only AGP and PCI-e The PowerEdge 6800/6850 features Memory RAID technology. = True False The BMC firmware on a PE850 can be updated via a USB memory key. False = True BMC Firmware installation is supported under the following operating systems: = Windows 2000 = Windows Server 2003 HP Unix = Red Hat Enterprise Linux 3 i386 With Dell OpenManage Array Manager 2.5 or later installed, DSET gathers information on: = Enclosures SDRAM memory = PERC controllers = Array/containers The ESM log can be cleared using the DSET utility. = True False Which of the following PowerEdge system board firmware can be updated within Windows 2003? = BIOS Modem = ESM = BMC BIOS on a Dell system can be updated from the following devices: = Diskette = USB memory key = Flash memory chip = CD-ROM In which section of the system setup of the PowerEdge 830 would you ensure that the diskette drive is the first boot device? = Boot sequence Diskette Drive under Integrated Devices System boot Drives Which component is not required to complete POST on the PowerEdge 830? = Hard-disk drive Memory System board Processor The PowerEdge 6850 has a media bay that accepts two additional hard-disk drives. True = False Which of the following FRUs are offered as hot pluggable in the PowerEdge 6800? Memory riser boards = System fans = Power supplies = Hard-disk drives The PowerEdge SC430 supports operating system based RAID 0 and RAID 1. = True False How many USB ports are on the front of the PowerEdge SC430? 4 0 1 = 2 When using the SC RAID Manager software, which RAID controllers are supported ? PERC 4/DC = Adaptec 39320 = CERC SATA 6ch = CERC SATA 2s Which service must be set to Automatic in order to enable CD-R/CD-RW recording in Microsoft Windows Server 2003 on the PowerEdge SC430? CDR/CDRW Logical Disk Manager Distributed Transaction Coordinator = IMAPI CD-Burning COM Background Intelligent Transfer Service Which of the following PowerEdge SC430 replacement components ship with heat sink grease when being replaced? Hard-disk drive = Processor fan = Bezel =Power Supply Dell OpenManage Server Assistant helps users install a server operating system. False = True The DSA CD can be used to install Red Hat Linux on a server. = True False The Dell Server Assistant (DSA) CD-ROM provides the following: = System configuration = Installation support = Device drivers Server performance ratings Virtual disks can be created using a Dell PERC 4/di controller. = True False Dell's RAID controllers support the following levels: = 0 30 = 50 = 1 Which memory module is not supported on the PowerEdge 850? = 256 MB DDR2 400 MHz unbuffered SDRAM DIMM 512 MB DDR2 533 MHz unbuffered SDRAM DIMM 1 GB DDR2 667 MHz unbuffered SDRAM DIMM 2 GB DDR2 667 MHz unbuffered SDRAM DIMM Which video controller is integrated on the system board of the PowerEdge 830? = XGI XG20 PCI No video controller is inetgrated - a PCI card is used ATI Radeon 7000-M ATI Rage XL Which component is faulty if the PowerEdge 830 displays a yellow-yellow-green-yellow diagnostic LED code? System board Video card Memory = Processor Spare bank and memory mirroring can be enabled at the same time on the PowerEdge 6850. = False True How many riser cards are available on the PowerEdge 850? 3 = 1 2 0 Without hyperthreading, how many data threads can a dual core processor handle on the PowerEdge 850? 1 4 3 = 2 Memory must be installed as follows in the PowerEdge 6850: Every other slot on the riser card In pairs (single-rank only) Both banks per riser card = In pairs (ranks must match within the bank) Which video controller is integrated on the system board of the PowerEdge 830? ATI Radeon 7000-M = XGI XG20 PCI No video controller is inetgrated - a PCI card is used ATI Rage XL The PowerEdge 6850 has a dedicated slot for an Integrated Fibre Channel Module. = True False The PowerEdge 6800/6850 features Memory RAID technology. False = True Demand Based Switching (DBS) on the PowerEdge 6800/6850 is designed to achieve: Better I/O bus resource management = Reduced power consumption Faster switching between tasks Better use of memory Memory size may be increased dynamically at run-time using the hot add capability of the chipset on the PowerEdge 6850 when the following conditions are met: Supported OS and empty memory slots in the riser System power must be turned off and open riser slots must be available OS independent and open slots on the riser = Supported OS and existing empty riser slot BMC Firmware installation is supported under the following operating systems: = Red Hat Enterprise Linux 3 i386 HP Unix Windows 2000 = Windows Server 2003 With Dell OpenManage Array Manager 2.5 or later installed, DSET gathers information on: = Array/containers = PERC controllers = Enclosures SDRAM memory The ESM log can be cleared using the DSET utility. False = True BIOS on a Dell system can be updated from the following devices: = USB memory key = Diskette = Flash memory chip = CD-ROM The system BIOS on a PowerEdge Server can be updated within Red Hat. = True False What is the first step in the EasyExchange process on the PowerEdge 830? Disconnect the SCSI cable from the drive Remove the side cover = Turn the system power off Remove the bezel How tall is the PowerEdge 850? = 1U 2U 5U 7U Which of the following FRUs are hot-pluggable in the PowerEdge 6850? = Power supplies = Memory riser boards = PCI-e Floppy/CDROM combo Which of the following FRUs are offered as hot pluggable in the PowerEdge 6800? Memory riser boards = Hard-disk drives = System fans = Power supplies How many USB ports are on the front of the PowerEdge SC430? = 2 0 4 1 Which of the following processors is a dual core processor on the PowerEdge SC430? Pentium 4521 Pentium 4630 = Pentium D830 Pentium 4665 Which of the following PCI-e slot options are available in the PowerEdge SC430? = X8 PCI-e slot linked at X4 speed X16 PCI-e slot linked at X8 speed = X1 PCI-e slot X4 PCI-e slot When using the SC RAID Manager software, which RAID controllers are supported ? PERC 4/DC = CERC SATA 6ch = CERC SATA 2s = Adaptec 39320 A customer has a PowerEdge SC430 system that will not POST and is displaying a 1-4 diagnostic LED code. What is most likely the faulty component? = System board Processor Memory Hard disk To remove the front system fan in a PowerEdge SC430, you must first remove which components: System board = Cover = AC Power cable = Heatsink A customer has a PowerEdge SC430 system that will not POST and is displaying a 3-4 diagnostic LED code. What is most likely the faulty component?!!! Processor System board = Memory ~~p Hard-disk driv Memory is only hot-plugged in the PowerEdge 6850 when: A redundant memory configuration is active A spare blank is active The system is powered off = Only RAID memory is active The Dell Smart USB flash drive can be made a bootable device. = True False An additional PCI SCSI/RAID controller is required to support the 1x10 + 1x2 hard-disk drive configuration on the PowerEdge 6800. True False RAID Management utilities that provide error statistics logging are dell open array manager bios linux The BMC firmware on a PE850 can be updated via a USB memory key true DSET is a small intrusive tool that does not require reboot of the system. true )