What components are field replaceable on the PowerConnect 5212? Power Supply v Network Switch Fan pack v SFP The PowerConnect 5224 has a red power LED illuminated when the internal power supply has failed. v True False On a PowerConnect 3248, which command would set a port to 10 Mb full duplex at the 'Console(config-if)#' prompt? speed 10full v speed-duplex 10full speed-duplex 100half speed-fullduplex 10mb A PowerVault 220S and a PowerVault 221S have indicator LEDs on which of the following modules? v The front panel The active cooling module The enclosure management module Split-bus module On the PowerEdge 6600, you can only remove and replace one power supply at a time when the system is powered on. v True False What is the embedded RAID option on a PowerEdge 4600? PERC 2/DI v PERC 3/DI PERC 3/SI PERC 2/SI If the ROMB hardware is installed, what system setup option on the PowerEdge 2650 allows you to enable or disable the embedded RAID controller? v Integrated devices Embedded server management PCI IRQ assignment Boot sequence What is the maximum number of processor(s) that can be installed in a PowerEdge 400SC? v One Two Three Four What is the cause of a 3-4-2 beep code error that occurs during a PowerEdge 400SC system startup? DMA initialization failure v Screen-retrace test failure or test in progress System configuration check failure Time of day-clock stopped What does a GATE A20 failure message indicate on the PowerEdge 650? NVRAM_CLR jumper is installed v Faulty keyboard controller Improperly installed memory module Bad mouse cable What must be replaced if the Time of Day clock fails on the PowerEdge 650? Power supply Backplane DIMMs v System board coin battery A blue blinking system status indicator on the PowerEdge 650 indicates? There is activity on the NIC The power is off A fault with the hard-disk drive v The system is identifying itself What does a 4-3-1 beep code indicate on the PowerEdge 1750? No memory installed Faulty mouse cable v Improperly installed, or faulty memory modules Cache test failure, or faulty microprocessor What system setup option on the PowerEdge 1750 allows you to set the maximum memory available to the operating system to 256 MB? Integrated devices PCI IRQ assignment Embedded server management v OS install mode How many processors will the PowerEdge 1750 support? One Four v Two Three When Array Manager is loaded on a system running Windows 2000 Server, what happens to the native disk management utility? v It is replaced by Array Manager. The native uutilities functionality is combined with Array Manager. The native utility operates in the backgroud. Nothing, both can be used. The SNMP community name cannot be specified during a Windows 2000 installation when using the Dell OpenManage Server Assistant CD. v True False What operating systems can IT Assistant be installed on? Red Hat Linux v Windows 2000 Professional v Windows XP Novell Netware What RAID level does NOT provide fault tolerance? RAID 0 RAID 1 v RAID 3 RAID 5 To install Server Administrator, you will need to select the Install Management Station button when prompted for Select System Type. v True False What functions can be performed from the Quick Access menu in Dell OpenManage Array Manager? Set policies Run Diagnostics v Create a volume v Remote Management What Server Administrator tab allows you to view the POST logs? Properties Diagnostics v Logs Shutdown The acronym RAID stands for: Redundant Array of Interconnected Disks Reliable Array of Inexpensive Drives v Redundant Array of Independent Disks Reliable Array of Inexpensive Disks To install IT Assistant, must select the Install Management Station button when prompted to select the system type. False v True The Diagnostic Service is installed by default when installing Server Administrator. False v True Dell OpenManage Array Manager manages storage resources on remote stations with the following operating system: v NT 4.0 Server Windows 98 Netware 5.0 v Windows 2000 Advanced Server hen a new version of IT Assistant is installed over an older one, the installation program saves the current IT Assistant database. False v True Array Manager supports AMI/LSI and Adaptec based PERCs. False v True Which keys must be pressed to access the PERC 2, 2/Si, 3/Si or 3/Di BIOS configuration utility? v Which of the following firmware interfaces are available on the PERC 3/DCL, PERC, 3/DC, and PERC 3/QC? Ctrl-Q: Quick Setup Utility v Ctrl-M: Adapter BIOS Utility v Ctrl-H: WebBIOS Utility Ctrl-G: GUI BIOS Utility o What components are field replaceable on the PowerConnect 5212? = Network Switch = SFP Power Supply Fan pack oThe white RPS connector on the back of the PowerConnect 5224 is used for: downloading firmware to the switch. = connecting to a redundant power system. cascading switches. managing the switch Network devices can communicate through a PowerConnect 3248, whether the Ethernet cable is straight-through or crossover. False = True oWhat type of serial cable must be used when connecting to the PowerConnect 3248? = Null Modem serial cable Straight-through serial cable Firewire cable USB cable oWhat command saves the PowerConnect 5212 switch's running configuration to the startup configuration? move running-conf startup-conf save running-cfg startup-cfg copy start-cfg running-cfg = copy running-config startup-config Configuration changes made to the PowerConnect 5212 running-config are automatically stored in non-volatile memory. = False True What is the default username and password, to manage the PowerConnect 3248 in Privileged Exec mode? 'admin','admin' 'user','privilege' == 'admin', 'password' 'administrator', blank password When logged in to a PowerConnect 3248 as 'guest', Ethernet port settings can be adjusted via HyperTerminal. = True False When replacing an EMM on the powerVault 220S or PowerVault 221S, what can be done to ensure data is not lost due to improper termination? Quickly insert a terminator module into the empty slot. Switch the enclosure into cluster mode. =- Power down the enclosure. Remove all the split-bus modules. Port 5 on the PowerConnect 5224 switch has an FDX LED that is NOT illuminated and the LNK/ACT is randomly blinking orange, which indicates that port 5 is: configured to 10/100Mbps at half-duplex. ???? connected with a crossover cable. not connected to any devices. having collision errors. When managing the PowerConnect 5212 switch through a web browser, where can you determine if a specific port has 'Fast Link' enabled? = System -> Spanning Tree -> Port Settings ??? System -> Link Aggregation -> Trunk Settings System -> Ports -> Configure System -> VLAN -> Port Configuration On the PowerVault 220S and PowerVault 221S the ______ LED will be on when the backplane is split into two separate SCSI buses. Cluster Fault Power = Split-bus ?? oThe default administrative VLAN for a PowerConnect 5212 is VLAN 0. True = False If neither the split-bus LED nor the cluster LED are illuminated, the enclosure is in cluster mode. = False True How many power supplies are required for the PowerEdge 6650 to operate normally? = Two Zero One Three The PowerConnect 5212 has 24 one gigabit Ethernet port. = False True oThe PowerEdge 2600 contains an RJ45 connector that can be used for the embedded remote access card option. False = True What is the embedded RAID option on a PowerEdge 4600? = PERC 3/DI PERC 3/SI PERC 2/SI PERC 2/DI If the ROMB hardware is installed, what system setup option on the PowerEdge 2650 allows you to enable or disable the embedded RAID controller? Embedded server management Boot sequence = Integrated devices PCI IRQ assignment What is the cause of a 3-4-2 beep code error that occurs during a PowerEdge 400SC system startup? System configuration check failure = Screen-retrace test failure or test in progress DMA initialization failure Time of day-clock stopped How many external USB ports are supported on the PowerEdge 400SC? Five = Six One Four With the PASSWD jumper installed on a PowerEdge 400SC, the password feature is disabled. = False True On a PowerEdge 400SC, what is the possible problem when the rear panel LED indicators are lit as follows: A=Red, B=Green, C=Red, D=Red? Loose connection on your printer. Loose or improperly connected mouse. Ethernet cable connected in wrong port. = PCI device configuration activity in progress or PCI device failure. What is the front side bus speed of a PowerEdge 400SC with a 2.0GHz Celeron processor? 800 MHz =400 MHz 133 MHz 233 MHz What does a GATE A20 failure message indicate on the PowerEdge 650? = Faulty keyboard controller Improperly installed memory module Bad mouse cable NVRAM_CLR jumper is installed What does a 3-3-1 beep code indicate on the PowerEdge 650? = CMOS failure BIOS error No memory installed Video ROM search failure What is the maximum number of processors that can be installed in the PowerEdge 650? Three Two = One Four What is the processor frontside bus speed on the PowerEdge 650? 200 MHz = 533 MHz ??? 100 MHz 133 MHz What system setup option on the PowerEdge 1750 allows you to set the maximum memory available to the operating system to 256 MB? = OS install mode PCI IRQ assignment Integrated devices Embedded server management What does a 4-3-1 beep code indicate on the PowerEdge 1750? No memory installed Faulty mouse cable = Improperly installed, or faulty memory modules Cache test failure, or faulty microprocessor What must be replaced if an Unsupported CPU stepping detect error message is displayed on the PowerEdge1750? = CPU System board ERA/O System memory What must be replaced if the Time of Day clock fails on the PowerEdge 650? Power supply Backplane = System board coin battery DIMMs The minimum amount of RAM supported in a PowerEdge 400SC is 256 MB. = False True What management protocol must be installed and configured prior to installing Server Administrator? DHCP RIP = SNMP SMTP What Server Administrator tab allows you to view the POST logs? = Logs Properties Shutdown Diagnostics Which keys must be pressed to access the PERC 2, 2/Si, 3/Si or 3/Di BIOS configuration utility? = When a new version of IT Assistant is installed over an older one, the installation program saves the current IT Assistant database. True = False ??? ?What functions can be performed from the Quick Access menu in Dell OpenManage Array Manager? Set policies ? Create a volume ? Run Diagnostics ? Remote Management ? Array Manager supports AMI/LSI and Adaptec based PERCs. False = True The Diagnostic Service is installed by default when installing Server Administrator. = True False Which of the following firmware interfaces are available on the PERC 3/DCL, PERC, 3/DC, and PERC 3/QC? = Ctrl-H: WebBIOS Utility = Ctrl-M: Adapter BIOS Utility Ctrl-G: GUI BIOS Utility Ctrl-Q: Quick Setup Utility What operating systems can IT Assistant be installed on? Windows XP ? Novell Netware Red Hat Linux Windows 2000 Professional ? System storage can be set up using the Dell OpenManage Array Manager Tool from the Dell OpenManage Server Assistant CD. False = True What RAID level does NOT provide fault tolerance? RAID 1 = RAID 0 RAID 5 RAID 3 To install Server Administrator, you will need to select the Install Management Station button when prompted for Select System Type. False = True ?? When Array Manager is loaded on a system running Windows 2000 Server, what happens to the native disk management utility? = It is replaced by Array Manager. The native uutilities functionality is combined with Array Manager. The native utility operates in the backgroud. Nothing, both can be used. To install IT Assistant, must select the Install Management Station button when prompted to select the system type. False = True What utilities are contained in the utility partition created using the Dell OpenManage Server Assistant CD? Server Administrator = Server Diagnostics = RAID Utility BIOS Update Utility ?When using Telnet, changes made to the running configuration will automatically be saved to the startup configuration on a PowerConnect 3248. = False True What tool is required when replacing a PowerConnect 5224 mounted in a Dell rack? T-20 Torx Driver Flathead Screwdriver 5/8' Open Ended Wrench = #2 Phillips-Head Screwdriver oWhat is the default IP address of a PowerConnect 5212? 10.1.1.1 = 0.0.0.0 192.16.0.1 10.3.2.1 After replacing a PowerConnect 3248, the switch's web interface can be accessed without first configuring the IP address via the serial cable. True = False The PowerConnect 5212 has a red power LED illuminated, which indicates: The fan pack needs to be replaced. The switch is in hibernate mode. The firmware is being updated. = The internal power supply has failed the absence of SNMP management software, what type of file transfer server must be used to update the PowerConnect 3248 firmware? HTTPS HTTP FTP = TFTP What command would test basic connectivity of a PowerConnect 5224 switch? = ping path = nbtstat = ipconfig The PowerVault 220S and the PowerVault 221S support up to 12 1-inch Ultra-3 SCSI hard-disk drives. = False True The Enclosure Management Modules on the PowerVault 220S and PowerVault 221S are hot-swappable. =false When replacing an EMM on the powerVault 220S or PowerVault 221S, what can be done to ensure data is not lost due to improper termination? Quickly insert a terminator module into the empty slot. Switch the enclosure into cluster mode. Power down the enclosure. Remove all the split-bus modules. On the PowerEdge 6600, what is the minimum number of power supplies required for the operating system to operate normally? = Two Three One Four The processor VRMs on the PowerEdge 4600 are soldered to the system board. True = False oA PowerVault 220S and a PowerVault 221S have indicator LEDs on which of the following modules? The active cooling module = The front panel = Split-bus module = The enclosure management module What is the maximum number of Xeon processors that a PowerEdge 2650 will support? Three The PowerEdge 2650 does not support Xeon processors. One = Two What are the minimum and maximum amounts of memory that can be installed in a PowerEdge 400SC? 512 MB ? 2 GB 256 MB ? 4 GB = 128 MB ? 4 GB 128 MB ? 2 GB If the power button is disabled in the PowerEdge 650 system setup, the system can be powered on but cannot be powered off using the power button. = True False The PowerEdge 1750 has ________ embedded Broadcom NetXtreme Gigabit NICs. = Two One Three Zero What feature allows clearing of the system password in the event the system password is forgotten or becomes corrupted on the PowerEdge 650? Pressing the power button three times Removing the coin battery on the systemboard = The password jumper on the system board System security option in the system BIOS How many processors will the PowerEdge 1750 support? Three = Two Four One On the PowerEdge 650, the default position of the NVRAM_CLR jumper is set to enabled (jumpered). True = False Dell OpenManage Array Manager manages storage resources on remote stations with the following operating system: = NT 4.0 Server ? Netware 5.0 Windows 98 = Windows 2000 Advanced Server ? The SNMP community name cannot be specified during a Windows 2000 installation when using the Dell OpenManage Server Assistant CD. True = False ? Which keys must be pressed to access the PERC 2, 2/Si, 3/Si or 3/Di BIOS configuration utility? = Which of the following can be selected when installing Management Station Applications? = Remote Management TCO Database Server = Array Manager = IT Assistant oWhat two files can the customer upgrade without support intervention on a PowerConnect 5212? loader file = opcode file diag file = config file What type of memory does the PowerEdge 4600 use? = DDR SDRAM EDO SDRAM Rambus The PowerConnect 5224 has a red power LED illuminated when the internal power supply has failed. = True False When the PowerVault 220S or PowerVault 221S is operating outside of its specified thermal range, the thermal LED will be: Red in color Blinking red Blinking amber = Amber in color What is the maximum number of Xeon microprocessors that a PowerEdge 6600 or 6650 will support? Three Two One = Four What is the number of rack units the PowerVault 220S occupies? Two = Three One Four If a PowerConnect 5224 switch reports an 'Invalid IP address' while configuring the switch's IP address, you should: reboot the switch. replace the switch. update the firmware on the switch. = use a different IP address. A blue blinking system status indicator on the PowerEdge 650 indicates? There is activity on the NIC A fault with the hard-disk drive The power is off = The system is identifying itself When replacing a power supply or an active cooling fan attached to the power supply on a PowerVault 220S or PowerVault 221S in a non-redundant configuration, you must _______ the enclosure before you begin. = Power off Dissconnect Initialize Reboot On the PowerEdge 6600, you can only remove and replace one power supply at a time when the system is powered on. = True False The PowerEdge 400SC has an embedded Gigabit Ethernet NIC. False = True What option must be installed to support eight hard-disk drives internally on the PowerEdge 2600? 1 x 8 SCSI backplane ROMB hardware = Peripheral bay backplane Split backplane card What is the maximum number of PCI cards that can be installed in a PowerEdge 400SC? Three = Four Five Two The PowerEdge 650 has ________ DIMM sockets. Four The acronym RAID stands for: Reliable Array of Inexpensive Drives Redundant Array of Interconnected Disks Reliable Array of Inexpensive Disks ! Redundant Array of Independent Disks What is the minimum and maximum amount of memory that can be supported by the PowerEdge 650? 512 K/2 GB 256 MB/1 GB = 128 MB/4 GB 1 GB/8 GB Multiple chioce: What is the purpose of expanding a virtual disk using Dell OpenManage Array Manager? To recover from a failed drive. = To add a disk to an existing array. To decrease the size of an existing array. To change disk type. What must be specified when creating a virtual disk using Dell OpenManage Array Manager? Format type Set the permissions for the virtual disk to read only Disk name = The virtual disk size ++++++++++++++++++++++++++++++++++++++++++++++++++++++ 1 What components are field replaceable on the PowerConnect 5212? Yes 2 Port 5 on the PowerConnect 5224 switch has an FDX LED that is NOT illuminated and the LNK/ACT is randomly blinking orange, which indicates that port 5 is: Yes 3 When managing the PowerConnect 5212 switch through a web browser, where can you determine if a specific port has 'Fast Link' enabled? Yes 4 On the PowerVault 220S and PowerVault 221S the ______ LED will be on when the backplane is split into two separate SCSI buses. Yes 5 On the PowerEdge 6600, what is the minimum number of power supplies required for the operating system to operate normally? Yes 6 The processor VRMs on the PowerEdge 4600 are soldered to the system board. Yes 7 If the ROMB hardware is installed, what system setup option on the PowerEdge 2650 allows you to enable or disable the embedded RAID controller? Yes 8 What is the cause of a 3-4-2 beep code error that occurs during a PowerEdge 400SC system startup? Yes 9 On a PowerEdge 400SC, what is the possible problem when the rear panel LED indicators are lit as follows: A=Red, B=Green, C=Red, D=Red? Yes 10 What is the maximum number of processors that can be installed in the PowerEdge 650? Yes 11 What does a GATE A20 failure message indicate on the PowerEdge 650? Yes 12 If the power button is disabled in the PowerEdge 650 system setup, the system can be powered on but cannot be powered off using the power button. Yes 13 How many processors will the PowerEdge 1750 support? Yes 14 What does a 4-3-1 beep code indicate on the PowerEdge 1750? Yes 15 What system setup option on the PowerEdge 1750 allows you to set the maximum memory available to the operating system to 256 MB? Yes 16 Which of the following can be selected when installing Management Station Applications? Yes 17 Multiple chioce: What is the purpose of expanding a virtual disk using Dell OpenManage Array Manager? Yes 18 What operating systems can IT Assistant be installed on? Yes 19 What functions can be performed from the Quick Access menu in Dell OpenManage Array Manager? Yes 20 What utilities are contained in the utility partition created using the Dell OpenManage Server Assistant CD? Yes 21 System storage can be set up using the Dell OpenManage Array Manager Tool from the Dell OpenManage Server Assistant CD. Yes 22 The Diagnostic Service is installed by default when installing Server Administrator. Yes 23 What RAID level does NOT provide fault tolerance? Yes 24 The acronym RAID stands for: Yes 25 Array Manager supports AMI/LSI and Adaptec based PERCs. Yes 26 To install Server Administrator, you will need to select the Install Management Station button when prompted for Select System Type. Yes 27 Dell OpenManage Array Manager manages storage resources on remote stations with the following operating system: Yes 28 What management protocol must be installed and configured prior to installing Server Administrator? Yes 29 When a new version of IT Assistant is installed over an older one, the installation program saves the current IT Assistant database. Yes 30 Which keys must be pressed to access the PERC 2, 2/Si, 3/Si or 3/Di BIOS configuration utility? Yes 83Á¡ ´ýÇÁ +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 1 What components are field replaceable on the PowerConnect 5212? Yes 2 Network devices can communicate through a PowerConnect 3248, whether the Ethernet cable is straight-through or crossover. Yes 3 When managing the PowerConnect 5212 switch through a web browser, where can you determine if a specific port has 'Fast Link' enabled? Yes 4 The PowerVault 220S and the PowerVault 221S support up to 12 1-inch Ultra-3 SCSI hard-disk drives. Yes 5 How many power supplies are required for the PowerEdge 6650 to operate normally? Yes 6 What is the embedded RAID option on a PowerEdge 4600? Yes 7 If the ROMB hardware is installed, what system setup option on the PowerEdge 2650 allows you to enable or disable the embedded RAID controller? Yes 8 What is the maximum number of PCI cards that can be installed in a PowerEdge 400SC? Yes 9 The PowerEdge 400SC has an embedded Gigabit Ethernet NIC. Yes 10 What feature allows clearing of the system password in the event the system password is forgotten or becomes corrupted on the PowerEdge 650? Yes 11 On the PowerEdge 650, the default position of the NVRAM_CLR jumper is set to enabled (jumpered). Yes 12 What is the minimum and maximum amount of memory that can be supported by the PowerEdge 650? Yes 13 What must be replaced if an Unsupported CPU stepping detect error message is displayed on the PowerEdge1750? Yes 14 The PowerEdge 1750 has ________ embedded Broadcom NetXtreme Gigabit NICs. Yes 15 How many processors will the PowerEdge 1750 support? Yes 16 Which of the following firmware interfaces are available on the PERC 3/DCL, PERC, 3/DC, and PERC 3/QC? Yes 17 When Array Manager is loaded on a system running Windows 2000 Server, what happens to the native disk management utility? Yes 18 Dell OpenManage Array Manager manages storage resources on remote stations with the following operating system: Yes 19 Which keys must be pressed to access the PERC 2, 2/Si, 3/Si or 3/Di BIOS configuration utility? Yes 20 Which of the following can be selected when installing Management Station Applications? Yes 21 What RAID level does NOT provide fault tolerance? Yes 22 Multiple chioce: What is the purpose of expanding a virtual disk using Dell OpenManage Array Manager? Yes 23 When a new version of IT Assistant is installed over an older one, the installation program saves the current IT Assistant database. Yes 24 To install Server Administrator, you will need to select the Install Management Station button when prompted for Select System Type. Yes 25 The Diagnostic Service is installed by default when installing Server Administrator. Yes 26 What must be specified when creating a virtual disk using Dell OpenManage Array Manager? Yes 27 What management protocol must be installed and configured prior to installing Server Administrator? Yes 28 The acronym RAID stands for: Yes 29 Array Manager supports AMI/LSI and Adaptec based PERCs. Yes 30 To install IT Assistant, must select the Install Management Station button when prompted to select the system type. Yes 83Á¡ ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 1 What tool is required when replacing a PowerConnect 5224 mounted in a Dell rack? Yes 2 The PowerConnect 5212 has a red power LED illuminated, which indicates: Yes 3 In the absence of SNMP management software, what type of file transfer server must be used to update the PowerConnect 3248 firmware? Yes 4 On the PowerEdge 6600, you can only remove and replace one power supply at a time when the system is powered on. Yes 5 The processor VRMs on the PowerEdge 4600 are soldered to the system board. Yes 6 What option must be installed to support eight hard-disk drives internally on the PowerEdge 2600? Yes 7 What is the number of rack units the PowerVault 220S occupies? Yes !!!! 8 If neither the split-bus LED nor the cluster LED are illuminated, the enclosure is in cluster mode. Yes 9 What does a GATE A20 failure message indicate on the PowerEdge 650? Yes 10 If the power button is disabled in the PowerEdge 650 system setup, the system can be powered on but cannot be powered off using the power button. Yes 11 The PowerEdge 1750 has ________ embedded Broadcom NetXtreme Gigabit NICs. Yes 12 What must be replaced if an Unsupported CPU stepping detect error message is displayed on the PowerEdge1750? Yes 13 The minimum amount of RAM supported in a PowerEdge 400SC is 256 MB. Yes 14 How many external USB ports are supported on the PowerEdge 400SC? Yes 15 With the PASSWD jumper installed on a PowerEdge 400SC, the password feature is disabled. Yes 16 What utilities are contained in the utility partition created using the Dell OpenManage Server Assistant CD? Yes 17 What RAID level does NOT provide fault tolerance? Yes 18 Array Manager supports AMI/LSI and Adaptec based PERCs. Yes 19 What functions can be performed from the Quick Access menu in Dell OpenManage Array Manager? Yes !!! 20 The Diagnostic Service is installed by default when installing Server Administrator. Yes 21 What management protocol must be installed and configured prior to installing Server Administrator? Yes 22 Which keys must be pressed to access the PERC 2, 2/Si, 3/Si or 3/Di BIOS configuration utility? Yes !!!! 23 Dell OpenManage Array Manager manages storage resources on remote stations with the following operating system: Yes 24 When Array Manager is loaded on a system running Windows 2000 Server, what happens to the native disk management utility? Yes 25 Multiple chioce: What is the purpose of expanding a virtual disk using Dell OpenManage Array Manager? Yes !!! 26 What Server Administrator tab allows you to view the POST logs? Yes 27 The acronym RAID stands for: Yes 28 Which of the following can be selected when installing Management Station Applications? Yes 29 The SNMP community name cannot be specified during a Windows 2000 installation when using the Dell OpenManage Server Assistant CD. Yes 30 To install IT Assistant, must select the Install Management Station button when prompted to select the system type. Yes 93Á¡