Before installing drivers for any of the QLogic HBAs in Windows 2003 you must first load the: ? Windows 2003 Fibre Channel Administration Patch = Windows 2003 STORport Driver Hotfix ?Windows 2003 SCSIport Driver Hotfix ?Windows 2003 security updates Updated QLogic HBA drivers can be obtained from the EMC OEM section on QLogic's website. FALSE = TRUE The Emulex LP982 HBA is not supported under Windows 2003. = FALSE TRUE The QLogic QLA200 HBA driver is installed using a wizard driven install program. FALSE =TRUE The Navisphere Server Utility can only be run directly from the CD. TRUE = FALSE The Navisphere Storage System Initialization Utility can be installed on a host or run directly from the CD. = TRUE FALSE Before installing drivers for any of the Emulex HBAs in Windows 2003 you must first load the: ? Windows 2003 Fibre Channel Administration Patch ?Windows 2003 SCSIport Driver Hotfix ?Windows 2003 security updates =Windows 2003 STORport Driver Hotfix The Navisphere Server Utility is included on the CD that ships with the Dell|EMC AX100 storage system. FALSE =TRUE PowerPath 3.06 is required for use with a Windows 2003 STORPort enabled HBA driver. ? FALSE =TRUE The Navisphere Storage System Initialization Utility is included on the CD that ships with the Dell|EMC AX100 storage system. ? FALSE =TRUE PowerPath allows automatic path failover. = TRUE FALSE PowerPath does not perform automatic path restoration. All paths must be manually restored after the issue has been resolved. = TRUE FALSE PowerPath 3.06 is required for use with a Windows 2003 STORPort enabled HBA driver. = TRUE FALSE The AX100 Storage Processor is not hot-swappable. Follow proper power-down procedure before removing an AX100 Storage Processor. Attempting to hot-swap a storage processor on an AX100 may result in unrecoverable data loss. = TRUE FALSE Each storage processor in the dual processor Dell|EMC AX100 are hot swappable and can be replaced without bringing down the entire array. TRUE =FALSE A Dell|EMC AX100 snapshot is a point-in-time copy of a virtual disk. = TRUE FALSE Before removing the power supply on a single processor Dell|EMC AX100 it must be properly powered down to avoid data loss. FALSE =TRUE The Dell|EMC AX100 single storage processor storage array does not support hot swapping of the hard drives. = FALSE TRUE Windows NT4 is not a supported operating system on the Dell|EMC AX100. = TRUE FALSE A single storage processor Dell|EMC AX100 with Drive 2 removed will ________. = Not complete the boot process. Complete the boot process. The battery backed cache card in the single processor Dell|EMC AX100 can maintain data for 72 hours. FALSE =TRUE Both storage processors on the dual processor Dell|EMC AX100 are hot swappable. TRUE =FALSE What type of serial cable is required to be connected between the host and the Brocade 3250 fabric switch during the EZ Switch Setup utility wizard? = Straight Serial Null-modem ------------------------------------------------------------------------------------------ Choose all that apply: The Navisphere Storage System Initialization Utility is used to configure the following: User Accounts for the AX100 storage system User Accounts for the Brocade 3250 FC switch Network parameters for the AX100 storage system Network parameters for the Brocade 3250 FC switch ------------------------------------------------------------------------------------------- Choose all that apply: Use the Navisphere Server Utility on each server attached to a Dell|EMC AX100 storage system after the following are performed: Install or configure third party applications. Install a new operating system, or upgrade or patch the existing operating system. Update file system information. For example, you mount new volumes or create new partitions. Change the host name and/or IP address of the server. ------------------------------------------------------------------------------------------ True/False A Dell|EMC AX100 snapshot is a point-in-time copy of a virtual disk. FALSE **TRUE ----------------------------------------------------------------------------------------- Multiple choice: When the PowerPath Monitor icon in the system tray of the windows desktop displays a single red slash mark it is indicating the following: Server Not Responding - Can not communicate with Monitor service. This occurs if the PowerPath Administrator Suite encountered errors during initialization. Standard - PowerPath is optimal. All configured paths are operating properly. **Degraded - Some but not all paths have failed. All Failed - All configured paths have failed. ------------------------------------------------------------------------------------------ ' Multiple choice: A dual storage processor Dell|EMC AX100 contains ________ hard-disk drives minimum and up to ________ maximum .' 4, 15 3, 12 3, 15 **4, 12 ------------------------------------------------------------------------------------------- Multiple choice: The single storage processor Dell|EMC AX100 arrays require the first ________ disks to be installed before the array will complete the boot process. 5 **3 2 4 ------------------------------------------------------------------------------------------- Multiple choice: Both the single and dual storage processor Dell|EMC AX100 arrays support up to ________ SATA hard drives. 15 10 **12 4 ------------------------------------------------------------------------------------------- True/False The UPS on the dual storage processor Dell|EMC AX100 provides power long enough for cached data to be wrote to disk before an orderly shutdown of the array is performed. FALSE **TRUE --------------------------------------------------------------------------------------------- Multiple choice: The LEDs on the Battery Back Up Cache Board of a single storage processor Dell|EMC AX100 are displaying flashing green, solid amber, and solid blue. This indicates the following state: Power off, No failures, LIVE data **Power on/batteries charging, Critical failure, LIVE data Power on/batteries charged, Critical failure, LIVE data Power on/batteries charged, Critical failure, no valid data -------------------------------------------------------------------------------------------- True/False On a dual storage processor Dell|EMC AX100 both storage processors contain only one front end fibre channel port. TRUE **FALSE -------------------------------------------------------------------------------------------- True/False The Brocade 3250 Fabric Switch is pre-zoned from the factory. FALSE **TRUE --------------------------------------------------------------------------------------------- True/False A Dell|EMC AX100 hot spare is a single spare disk, which serves as a temporary replacement for a failed disk in a disk pool. Each disk pool must have its own hot spare. **FALSE TRUE --------------------------------------------------------------------------------------------- True/False When you replace the failed disk on the Dell|EMC AX100, the storage controller copies the data from the hot spare onto the replacement disk. The storage controller automatically frees the hot spare to serve as a hot spare again. FALSE **TRUE ---------------------------------------------------------------------------------------------- True/False A disk pool in the Dell|EMC AX100 is a set of disks on which you create one or more virtual disks. **TRUE FALSE ------------------------------------------------------------------------------------------- True/False A quick Install guide is supplied in the box that the Dell|EMC AX100 ships in. **TRUE FALSE -------------------------------------------------------------------------------------------- True/False During the install of a Dell|EMC AX100 the technician must demonstrate to the end user how to create and assign Virtual disks to hosts. **TRUE FALSE --------------------------------------------------------------------------------------------- True/False The Brocade EZ Switch Setup utility must be run directly from the CD because it is not possible to install it on the host. TRUE **FALSE --------------------------------------------------------------------------------------------- True/False The Dell|EMC AX100 can be installed in both a single and dual fabric SAN configuration. **TRUE FALSE --------------------------------------------------------------------------------------------- Choose all that apply: Which of the following HBAs are supported HBAs for the Dell|EMC AX100 QLogic QLA2340 QLogic QLA200 QLogic QLA2200 Emulex LP982 ------------------------------------------------------------------------------------------- True/False Windows 2000 is not a supported operating system on the Dell|EMC AX100. TRUE **FALSE -------------------------------------------------------------------------------------------- True/False Each of the eight Fibre Channel ports on the Brocade 3250 can negotiate to either 1 Gbit/sec or 2 Gbit/sec speed. FALSE **TRUE -------------------------------------------------------------------------------------------- Multiple choice: The Brocade 3250 Fabric Switch provides ________ FC ports in a 1 U chassis. 24 16 4 **8 -------------------------------------------------------------------------------------------- Multiple choice: On the Brocade 3250 Fabric Switch, a port LED that is solid green indicates the following: No light or signal carrier (no module, no cable) for media interface LEDs Online and frames flowing through port. Receiving light or signal carrier, but not yet online **Online (connected with device over cable) ----------------------------------------------------------------------------------------------- The Navisphere Express software consists of a proprietary operating environment and a web-based user interface (UI). Both the operating environment and the UI are installed, at the factory, on the storage controllers in the AX100 storage system **TRUE FALSE ---------------------------------------------------------------------------------------------------- 'True/False The Diagnostic Files option in the services menu of Navisphere Express selection allows you to download the log files from each storage processor in the Dell|EMC AX100 ' **TRUE FALSE -------------------------------------------------------------------------------------------- True/False Only 24U Dell PowerEdge racks are supported solutions for the Dell|EMC AX100. TRUE **FALSE -------------------------------------------------------------------------------------------- The QLogic QLA200 HBA driver is installed using a wizard driven install program. FALSE TRUE ------------------------------------------------------------------------------------------- Multiple choice: The ________ is used to manage access to snapshots on the Dell|EMC AX100. Navisphere Express GUI PowerPath Administrator Navisphere Server Utility Navisphere Storage System Initialization Utility ------------------------------------------------------------------------------------------- Multiple choice: Which of the following features allows the single processor Dell|EMC AX100 to back up the write cache in the event of a power loss? Write cache is not backed up on the single processor array. A UPS. The Battery Back Up Cache Board. An SPS. ------------------------------------------------------------------------------------------ Multiple choice: The Dell|EMC AX100 will occupy ________ U in a Dell PowerEdge Rack. 3 4 7 2 ------------------------------------------------------------------------------------------- True/False An FTP server is required to update the firmware of a Brocade 3250 Fabric Switch. TRUE FALSE ------------------------------------------------------------------------------------------- Multiple choice: To update the Operating environment of the Dell|EMC AX100 select ________ from the left hand navigation in Navisphere Express. Software Settings Language Storage System -------------------------------------------------------------------------------------------- True/False A Dell|EMC AX100 virtual disk looks like an individual disk to the server's operating system and each virtual disk can be assigned to a different user, server, or application. TRUE FALSE