Which storage processor port number on a CX600 is matched with worldwide port name xx:xx:xx:63:xx:xx:xx:xx? SPB port 2 SPB port 1 v SPA port 3 SPA port 2 Which PowerPath license level is the minimum requirement to have front-end and back-end failover for a Dell | EMC CX700 installed in a Clariion only SAN? v PowerPath Enterprise PowerPath Base PowerPath Basic PowerPath Enterprise Plus Which of the following statements is true when cabling a Dell | EMC CX-400 for multipath? Both HBAs should see SPA_port_0 & SPB_port_0 and both HBAs should see SPA_port_1 & SPB_port_1 One HBA should see SPA_port_0 & SPA_port_1 while the other HBA should see SPB_port_0 & SPB_port_1 One HBA should see SPA_port_0 & SPB_port_0 while the other HBA should see SPA_port_1 & SPB_port_1 v One HBA should see SPA_port_0 & SPB_port_1 while the other HBA should see SPA_port_1 & SPB_port_0 Which troubleshooting method is available for a Dell | EMC CX-600 but not for a Dell | EMC CX-400? Monitoring POST with a hyperterminal session. v Port 80h codes POST Alphabet LED flash rate How many domains can a Dell | EMC CX-600 be a member of? v One Two Four Three Which command will retrieve Navisphere Agent information from a Dell | EMC CX-600's storage processor whose IP address is 10.38.45.76? navicli getagent –h 10.38.45.76 navicli –h 10.38.35.76 agentget v navicli –h 10.38.45.76 getagent navicli –h 10.38.45.76 get agent Which PowerPath command will manually restore the paths in PowerPath? powermt failback v powermt restore powerpath restore powermt trespass Which EMC utility is used to manage Emulex HBAs? v Elxcfg Elconfig Emlxcfg Emconfig Which of the following is the correct method for configuring the network settings on a new CX600 array's Storage Processors? Use a serial PPP session to configure SP-A and reboot it. Repeat for SP-B. Reconnect to SP-A using PPP and restart the management server on SP-A. Use a serial PPP session to configure SP-A and reboot it. Repeat for SP-B. Reconnect to SP-A using PPP and restart the management server. Repeat for SP-B v Use a serial PPP session to configure SP-A and reboot it. Repeat the same configuration steps for SP-B. Use a serial PPP session to configure SP-A and reboot it. Do not configure SP-B because it will obtain its network settings from SP-A automatically. What first must be done to change the storage domain membership of an already configured Dell | EMC CX600 array? Use the array's Navisphere Management UI to remove the array from its current domain. Use your browser to connect to the domain master SP over a serial cable connection and remove the array from its current domain. Perform a non-disruptive upgrade to reinstall the array's base code software. v Use the array's Navisphere Management UI to reset the domain security. When installing a QLogic HBA in a Windows based server for direct attached storage, what must be true for the HBA's configuration? v The QLogic Loop - Auto Map driver must be installed. The Connection Type BIOS setting must be set to 1. The Connection Type BIOS setting must be set to 0. The QLogic Fabric - Auto Map driver must be installed. How many longwave ISL's are required when cascading two Brocade DS32B2 switches? 2 minimum, 4 maximum v 1 minimum, 4 maximum Only 2 are supported Only 1 is supported Which procedure is correct for zoning a McData switch in a Dell | EMC environment? Create a zone, add ports to the zone, add the zones to the zone set v Create a zone, add WWNs to the zone, add the zone to the zone set Create an alias, add the alias to the zone, add the zone to the config Create a zone, add the zone to the alias, add the alias to the config What would the enclosure IDs be on a Dell | EMC CX700 array with 1 DAE-OS and 6 DAEs connected? v 0,0,0,0,1,1,1 0,1,2,3,0,1,2 0,0,1,1,2,2,3 0,1,2,3,4,5,6 When replacing an HBA in a server installed in a Dell | EMC SAN, what must be done for PowerPath to recognize the path of the new HBA? Remove the zone from the configuration, re-add it, then click enable. v Remove the old member's WWN from the HBA's alias and add the new member's WWN. Disable the configuration, add a new alias for the HBA and click enable. Create a new zone for the HBA and add it to the existing configuration.