What is the maximum number of supported DAE's that can be attached to a Dell | EMC CX-400? Four Two Five v Three Which storage processor port number on a CX600 is matched with worldwide port name xx:xx:xx:63:xx:xx:xx:xx? SPB port 2 SPB port 1 SPA port 2 v SPA port 3 Which of the following is NOT a requirement when enabling write cache on a Dell | EMC storage array? Functioning vault drives Two Fully charged SPS units Two functional fan packs in DPE v Two Power Supplies in DPE Which procedure is correct for zoning a McData switch in a Dell | EMC environment? v Create a zone, add WWNs to the zone, add the zone to the zone set Create an alias, add the alias to the zone, add the zone to the config Create a zone, add the zone to the alias, add the alias to the config Create a zone, add ports to the zone, add the zones to the zone set Which type of NaviSphere user account has read only rights on a CX700? v Monitor Administrator Manager Reader What would the enclosure IDs be on a Dell | EMC CX700 array with 1 DAE-OS and 6 DAEs connected? 0,0,1,1,2,2,3 v 0,0,0,0,1,1,1 0,1,2,3,4,5,6 0,1,2,3,0,1,2 Which parameters are required When connecting to a Dell | EMC DS-16-B2 (Brocade 3800) with a serial cable? Null modem ?9600, 8, None, 1, Hardware Null modem ?2400, 8, None, 1, None v Straight through cable ?9600, 8, None, 1, None Straight through cable ?2400, 8, None, 1, Hardware What is the default username and password for a Navisphere 6.x domain? v There is no default username and password. Username = admin and Password = password Username = Administrator and password = password Username = CLARiiON and password = CLARiiON! Which command will retrieve Navisphere Agent information from a Dell | EMC CX-600's storage processor whose IP address is 10.38.45.76? navicli –h 10.38.45.76 get agent navicli –h 10.38.35.76 agentget navicli getagent –h 10.38.45.76 v navicli –h 10.38.45.76 getagent Which EMC utility is used to manage Emulex HBAs? Emconfig Emlxcfg Elconfig v Elxcfg Which troubleshooting method is available for a Dell | EMC CX-600 but not for a Dell | EMC CX-400? POST Alphabet LED flash rate Monitoring POST with a hyperterminal session. v Port 80h codes If a user connects to a Dell | EMC storage enclosure through a supported web browser using Navisphere 6.x and inputs an invalid password, which type of access is granted? Read only access for the legacy arrays. Read only access for local array. v No access is granted to anything. Read only access for arrays in the domain. What first must be done to change the storage domain membership of an already configured Dell | EMC CX600 array? Use your browser to connect to the domain master SP over a serial cable connection and remove the array from its current domain. Perform a non-disruptive upgrade to reinstall the array's base code software. Use the array's Navisphere Management UI to remove the array from its current domain. v Use the array's Navisphere Management UI to reset the domain security. How is the connection established to a Dell | EMC CX-Series array when configuring it for the first time? v Establish the connection to the array via a standard Ethernet connection and a web browser with the IP of 192.168.1.1. Establish the connection via a telnet session to the array with a standard Ethernet connection and the default IP of 172.16.0.100. Establish a PPP connection to the default IP of 192.168.1.1 with a null modem cable connected to the array. Establish the connection via a HyperTerminal session to the array with a null modem cable and the default IP of 172.16.0.100. A customer has added a new host to their Dell | EMC SAN. They have bound LUNs for the host to use and added the LUNs to a storage group, but the host does not have access to the LUNs. Navisphere shows the connectivity status of the HBAs in the host as blue. What needs to be done to provide the host access to the LUNs? Add the host to the storage group with the luns. v Restart the Navisphere Agent service. Install and enable Access Logix. Edit the agent.config file and add privileged users.