90% ------------------------------------------------------------------------------------------------------------------------- -------------------------------------------------------------------------------------------- Which one of the following settings is NOT valid when partitioning a PV132T? Slot Configuration Partition Enable Drive Mode ** Library Mode Which of the following methods can be used to flash the library firmware of a PowerVault 136T? * RMU PV-Tools * Dell Library & Tape Tools * Library Serial Port Which configuration is correct for a PowerVault 132T with two tape drives installed and two separate hosts connected running unique backup applications? A PowerVault 132T with 2 SDLT-320 drives, an Adaptec 39160 installed in each host and LUN partitioning enabled on the PV132T. None, this configuration is not supported. NetBackup is the only Tape drive software which supports this configuration and it must have the Master Server option installed. ** A PowerVault 132T with 2 LTO or LTO2 drives, an Adaptec 39160 instaled in each host and LUN partitioning enabled on the PV132T. Which component is used to attach a PV136T LTO Library to a SAN? ** FC Bridge PV35F PV211S RMU Which if the following PV136T components have Serial Ports? = RMU FC Bridge SCSI Host Interface PCBA Tape Drive Module If you cannot enable LUN partitioning on a PowerVault 132T with SDLT-320 drives installed, what is the problem? The host does not have the correct driver installed. The SDLT-320 drives do not have the correct firmware installed. ** None, the SDLT 320 drive does not support LUN partitioning. The tape drives are not terminated correctly. After installing and configuring a new PowerVault 132T, the library controller is not recognized by the Adaptec 39160 during POST; but a single drive is recognized. What is most likely the problem? ** The PowerVault 132T has LUN partitioning enabled, but the Adaptec 39160 does not have Multi-LUN support enabled. The PV132T library controller driver has not been installed. The host was not rebooted after installing the tape drive software. The Adaptec 39160 driver has not been installed. What are the requirements for enabling LUN partitioning on a PowerVault 132T with two LTO2 drives installed? ** Library firmware version 227D and LTO2 drive firmware version 37RH. The LTO2 drive does not support LUN partitioning. Library firmware version 224D and LTO2 drive firmware version 29C4. All firmware versions support LUN partitioning. It needs to be enabled through the PV132T's setup menu. On a server attached to a PV136T LTO Library, a user is able to remotely access the Operator Panel through the RMU. False ** True On a PowerVault 136T, how is the Fibre Channel Bridge's IP Address configured? Through the RMU web interface. HyperTerminal session using a straight-through cable. **HyperTerminal session using a null modem cable. Through the control panel of the PowerVault 136T. What is the difference between SNC manager versions 3.2.1 and 3.2.2? SNC manager 3.2.2 adds support for ArcServe 9.0 on a SAN. SNC manager 3.2.2 adds support for TapeWare 2.2 on a SAN. **SNC manager 3.2.2 adds support for the PV 136T SNC-2. SNC manager 3.2.2 adds support for partitioning on the PV 132T. After replacing one of the LTO-2 tape drives in a PowerVault 132T, only one tape drive is being detected. What is the most likely problem? The replacement LTO2 drive is bad and must be replaced. ** There is a conflict in SCSI ID's. Verify and change the SCSI ID of the new tape drive. The library controller is bad and needs to be replaced. The Drive Count setting must be set to 2 by running the Setup Wizard. How many data cartridge slots are available in an SDLT version PowerVault 136T with all optional columns installed and the door configured for mailbox? ** Fifty Seventy-Two Fourty-Five Sixty