Multiple Choice: On the PowerEdge 1855 server modules, what key must be pressed during POST to access the system setup? ** F2 F4 F8 F12 True/False: The PowerEdge 1855 server modules support booting to a USB floppy-disk drive, USB flash drive, and USB CD-ROM drive. ** True False Multiple Choice: How are the PowerEdge 1855 Ethernet PHY modules configured? ** The Ethernet PHY modules are passive devices and are not configurable. Using the DRAC/MC. Direct Serial connetion. Using telnet only. What three services will OpenManage storage management offer on the PowerEdge 1855? Blink Array/Disk, Prepare to remove, and Global Hot spare. ** Blink Array/Disk, Prepare to remove, and Rescan. Blink Array/Disk, Prepare to remove, and Global Failover recovery. Blink Array/Disk, Rebuild, and Global Rescan. True/False: The integrated PERC 4/IM in the PowerEdge 1855 supports Raid 5. True ** False Multiple Choice: What keys must be pressed during post on the PowerEdge 1855 as the PERC 4/IM is reconized, to enter the configuration utility? Esc and Alt Alt and X P and R ** Ctrl and M True/False: When conneted to the PowerEdge 1855 DRAC/MC through HyperTerminal, type connect switch-1 and press to connect to switch module 1. False ** True Multiple Choice: When conneted to the PowerEdge 1855 DRAC/MC through HyperTerminal, what command is used to get help on another DRAC/MC command? more ? ** help info True/False : The switch modules in the PowerEdge 1855 support Link Aggregation Groups participating in a VLAN. False ** True Multiple Choice: Each PowerEdge 1855 (PowerConnect 5316M) switch module has how many external Ethernet ports. Ten **Six Four Eight Multiple Choice: The Dell 2342M HBA on the PowerEdge 1855 has how many World Wide Node Names? Four ** One None Two Multiple Choice: The Dell 2342M HBA on the PowerEdge 1855 has how many World Wide Port Names? None ** Two One Four A customer reports that he has lost his BMC password for a PowerEdge 1855 and does not want to install OpenManage Server Administrator, how can this password be recovered? ** The customer can enter the BMC during POST using the CTRL+E option and replace his lost password. The customer must replace the system board; this password is not recoverable. The customer must boot to the ASSET utility to replace this password. The customer must re-flash the system BIOS to recover the password. A customer reports that when connecting to the BMC via Telnet on a PowerEdge 1855, during the console redirection session, the screen displays mostly unreadable characters. What must be done to resolve this issue? Inform the customer the SOL proxy must be re-installed; it seems corrupted. The system board must be replaced; it seems to have a faulty video controller. ** Inform the customer he must change the emulation type settings in the system BIOS to ANSI. Inform the customer he must change the console speed in the BIOS to 1200 baud. Multiple Choice What physical component must be installed for the TCP Offloading Engine (TOE) to function on the PowerEdge 1955? Second NIC ** TOE key Second processor NIC daughter card Multiple Choice Which precaution should be taken when replacing PowerEdge 1955 blade processors? Remove both processors at the same time Allow 10-15 minutes for the blade to cool ** Align the processor key with the slot Remove the DIMM heatsink Multiple Choice Which is the second step when removing the control panel on a PowerEdge 1955 blade? **Remove the two screws that hold the control panel board to the server blade frame Depress the cover release buttons Locate the retention clip that holds the ribbon cable Grasp the long edges of the daughter card and pull straight up vertically True/False: The PowerEdge 1855 hard-disk drives are hot swappable. False ** True Multiple Choice: What effect does removing the DRAC/MC have on I/O in the PowerEdge 1855? All data I/O and network I/O is paused on all server modules until the DRAC/MC is replaced. **Nothing. All I/O is stopped on all server modules and must be manually restarted after the DRAC/MC is replaced. Network I/O is stopped until the DRAC/MC is replaced. Multiple Choice: What component in the PowerEdge 1855 must be removed prior to removing network switch modules? The rack rails. The front bezel. The hard-disk drives. ** Nothing. Choose all that apply: What component must be removed from the PowerEdge 1855 prior to removing the midplane? System fans. Power supplies. DRAC/MC and all interconnect modules. Chassis control panel. Multiple Choice What feature prevents the PowerEdge 1955 blade from being inserted upside down? There is no mechanism to prevent this **A gravity lock on the server blade case The server blade is keyed to be inserted one way An alarm sounds before full insertion Multiple Choice What is a requirement for booting the PowerEdge 1955 to a USB flash drive? Change the Drive Emulation on the USB Key ** Change USB drive emulation to Auto in Setup during POST Enable NIC1 for PXE boot Disable NIC1 for PXE boot Multiple Choice What RAID types are supported on the PowerEdge 1955 SAS5/iR? ** 0 and 1 0 and 5 1 and 3 1 and 5 Multiple Choice How long is does it take before a system reboot will occur when upgrading the PowerEdge 1955 blade BIOS in Windows 2003? ** 30 seconds 60 minutes 60 seconds 30 minutes Multiple Choice What keystrokes are used to access the Baseboard Management Controller(BMC) during PowerEdge 1955 POST? Ctrl-R Alt-E ** Ctrl-E Ctrl-C Multiple Choice What keystroke allows entry to the System Setup program when pressed during system POST on the PowerEdge 1955? F1 F12 F10 ** F2 Multiple Choice Which tool is used to upgrade the DRAC/MC firmware in the PowerEdge 1955 chassis? TTP server FTP server ** TFTP server ISA server Multiple Choice What keystrokes are used to access the SAS5/iR controller configuration utility in the PowerEdge 1955? ** Ctrl-C Ctrl-A Alt-C Alt-A Which of the following is the proper procedure for rebuilding a failed hard-disk drive in the PowerEdge 1855? Power the blade down, check the jumpers on the replacement drive, and turn on the blade with the replacement drive installed. ** Ensure the blade is powered on and replace the faulty drive with the known good drive. Power the blade down, replace the failed drive, turn on the blade with the replacement drive installed, and select the rebuild option in OMSS. Power down the blade, insert the replacement drive, boot the menu, and select Rebuild from the options menu. A customer reports that he has changed from SCSI to RAID using the on-board PERC 4/IM on his PowerEdge 1855. He also reports that after performing this function he is getting the error at POST “F1 to continue or F2 to enter setup?screen. What must be done to resolve this issue? ** Performing this action is destructive to data and the O/S musrt be re-installed. Inform the customer that the system board seems to be faulty and it will need to be replaced. Inform the customer that he must wait for the rebuild to complete before the system will boot. Inform the customer that he must upgrade the BIOS to support the RAID function. A TFTP server is required to update the firmware on the PowerEdge 1855 DRAC/MC. ** True False True/False: A null-modem cable is used to create the connection between the DRAC/MC and the client system for configuration of the PowerEdge 1855. ** True False True/False : Each switch module only supports one VLAN on the PowerEdge 1855. True ** False True/False: To connect to the PowerEdge 1855 switch modules, at the DRAC/MC prompt in the HyperTerminal window type connect switch-1 or connect switch-2 and press the enter key. ** True False Multiple Choice: The PowerEdge 1855 Fibre Channel Pass through modules each have how many how many World Wide Port Names? Two for each port. Ten. ** None, since the device is passive. One. Multiple Choice: The PowerEdge 1855 Fibre Channel Pass through modules must be populated with what brand of SFP? IBM. ** Tyco. Agilent. Finisar. A reports the system board is faulty; he can not ping the BMC on his PowerEdge 1855 blade. What must be done to resolve this issue? This version of the firmware requires the switch ?T?to respond to an ICMP (ping) request. The BMC is not functioning correctly and the system board should be replaced. ** The BMC is functioning as designed, the BMC does not respond ICMP (ping) requests. The BMC will not respond ping while in use. Multiple Choice The asset tag utility should be used to change a PowerEdge 1955 blade service tag when Replacing both hard-disk drives A BIOS flash fails Replacing the processors ** Replacing the sytem board Multiple Choice What is the function of DIP switches 1 and 2 on the PowerEdge 1955? ** Clear NVRAM and reset BIOS password Enable the secondary NIC on the system board Set the BIOS back to the default password “calvin?/B> Reprogram NVRAM when flashing the system BIOS Multiple Choice Which version of the DRAC/MC firmware activates PowerEdge 1955 blades in the chassis? ** 1.3 1.1.1 1.2 1.1 Multiple Choice What command shows the offloaded TCP connections when TOE (TCP Offloading) is enabled on the PowerEdge 1955? ** netstat -ont netstat -mt netstat -tmo netstat -omt True/False: On the PowerEdge 1855 server modules, the system setup can be accessed by pressing F12 during POST. True **False True/False: The PowerEdge 1855 server modules supports booting to a USB flash drive. **True False Multiple Choice: The integrated PERC 4/IM in the PowerEdge 1855 supports what Raid level. RAID 0. RAID 3 **RAID 1. RAID 50 The Baseboard Management Controller (BMC) in the PowerEdge 1855 allows what type of console redirection? Text and GUI if using the 1.64 Firmware. GUI based only when using Hyper-Terminal and connecting throught the DRAC/MC to the BMC. **Text-based console redirection only. This version does not offer any console redirection services. Multiple Choice When removing memory DIMMS from the PowerEdge 1955, do the following first: **Allow 10-15 minutes for the server blade to cool Remove all DIMMS at the same time Remove the DIMM heatsink Remove DIMMS carefully using the memory removal tool Multiple Choice: What must be removed or disconnected before the microprocessor can be removed from the PowerEdge 1855? **The server module. The AC power. The hard-disk drives. The memory. True/False: The midplane on the PowerEdge 1855 is hot swappable. True ** False Multiple Choice What power supplies are supported with PowerEdge 1955 blades? 2200 watt 1900 watt 1200 watt **2100 watt Multiple Choice What is the default username and password when logging into the DRAC/MC on the 1955 blade server? calvin, root administrator, password **root, calvin admin, password How is the backplane bang in Windows 2003 on a PowerEdge 1955 blade removed? Install the backplane driver Install the RAID controller driver Install the system board driver Install the network controller driver Multiple Choice: What command is used to copy the running configuration to the startup configuration on the network switch modules in the PowerEdge 1855? copy config startup-config. copy running-configurations startup-configurations. move running-config startup-config. copy running-config startup-config. Multiple Choice: The PowerEdge 1855 Ethernet PHY modules only support what speed(s)? 100 Mbps. 100 Mbps and 1000 Mbps. 10 Mbps. **1000 Mbps. True/False: The integrated PERC 4/IM in the PowerEdge 1855 supports mirroring. **True False Multiple Choice: What OpenManage service may need to be stopped for the TFTP server, used to upgrade the firmware on the PowerEdge 1855 DRAC/MC, to function? Server service. SNMP service. FTP service. **OpForce service. Choose All That Apply: What interface options are available for management and configuration of the switch modules (PowerConnect 5316M) in the PowerEdge 1855? Server Administrator 2161DS Remote Console Switch Software GUI CLI Multiple Choice: What happens to the PowerEdge 1855 system when a power supply is removed from the chassis? All blades will power down. Blades 1-5 will power down. Nothing. **All blades will throttle down. Multiple Choice What tool is used to remove the PowerEdge 1955 system board? T-12 Torx driver Hex screwdriver Flat-blade screwdriver **Phillips-head screwdriver