What components are field replaceable on the PowerConnect 5212? Network Switch ! SFP Power Supply Fan pack Port 5 on the PowerConnect 5224 switch has an FDX LED that is NOT illuminated and the LNK/ACT is randomly blinking orange, which indicates that port 5 is: ! configured to 10/100Mbps at half-duplex. connected with a crossover cable. not connected to any devices. having collision errors. The default administrative VLAN for a PowerConnect 5212 is VLAN 0. True ! False If neither the split-bus LED nor the cluster LED are illuminated, the enclosure is in cluster mode. ?? False True How many power supplies are required for the PowerEdge 6650 to operate normally? ! Two Zero One Three What is the embedded RAID option on a PowerEdge 4600? ! PERC 3/DI PERC 3/SI PERC 2/SI PERC 2/DI If the ROMB hardware is installed, what system setup option on the PowerEdge 2650 allows you to enable or disable the embedded RAID controller? Embedded server management Boot sequence ! Integrated devices PCI IRQ assignment How many external USB ports are supported on the PowerEdge 400SC? Five ! Six One Four What is the front side bus speed of a PowerEdge 400SC with a 2.0GHz Celeron processor? 800 MHz ! 400 MHz 133 MHz 233 MHz What does a 3-3-1 beep code indicate on the PowerEdge 650? ! CMOS failure BIOS error No memory installed Video ROM search failure What is the maximum number of processors that can be installed in the PowerEdge 650? Three Two ! One Four What is the processor frontside bus speed on the PowerEdge 650? 200 MHz ! 533 MHz 100 MHz 133 MHz What system setup option on the PowerEdge 1750 allows you to set the maximum memory available to the operating system to 256 MB? !! OS install mode PCI IRQ assignment Integrated devices Embedded server management What does a 4-3-1 beep code indicate on the PowerEdge 1750? No memory installed Faulty mouse cable !! Improperly installed, or faulty memory modules Cache test failure, or faulty microprocessor What must be replaced if an Unsupported CPU stepping detect error message is displayed on the PowerEdge1750? ! CPU System board ERA/O System memory What management protocol must be installed and configured prior to installing Server Administrator? DHCP RIP !! SNMP SMTP What Server Administrator tab allows you to view the POST logs? ! Logs Properties Shutdown Diagnostics Which keys must be pressed to access the PERC 2, 2/Si, 3/Si or 3/Di BIOS configuration utility? ! When a new version of IT Assistant is installed over an older one, the installation program saves the current IT Assistant database. True # False What functions can be performed from the Quick Access menu in Dell OpenManage Array Manager? Set policies ! Create a volume Run Diagnostics ! Remote Management Array Manager supports AMI/LSI and Adaptec based PERCs. False ! True The Diagnostic Service is installed by default when installing Server Administrator. ?? True False Which of the following firmware interfaces are available on the PERC 3/DCL, PERC, 3/DC, and PERC 3/QC? ! Ctrl-H: WebBIOS Utility ! Ctrl-M: Adapter BIOS Utility Ctrl-G: GUI BIOS Utility Ctrl-Q: Quick Setup Utility What operating systems can IT Assistant be installed on? Windows XP ? Novell Netware Red Hat Linux Windows 2000 Professional ? System storage can be set up using the Dell OpenManage Array Manager Tool from the Dell OpenManage Server Assistant CD. False !! True What RAID level does NOT provide fault tolerance? RAID 1 !! RAID 0 RAID 5 RAID 3 To install Server Administrator, you will need to select the Install Management Station button when prompted for Select System Type. False ! True When Array Manager is loaded on a system running Windows 2000 Server, what happens to the native disk management utility? ! It is replaced by Array Manager. The native uutilities functionality is combined with Array Manager. The native utility operates in the backgroud. Nothing, both can be used. To install IT Assistant, must select the Install Management Station button when prompted to select the system type. False !! True What utilities are contained in the utility partition created using the Dell OpenManage Server Assistant CD? Server Administrator ! Server Diagnostics ! RAID Utility BIOS Update Utility What tool is required when replacing a PowerConnect 5224 mounted in a Dell rack? T-20 Torx Driver Flathead Screwdriver 5/8' Open Ended Wrench !! #2 Phillips-Head Screwdriver After replacing a PowerConnect 3248, the switch's web interface can be accessed without first configuring the IP address via the serial cable. True ! False What command would test basic connectivity of a PowerConnect 5224 switch? ! ping path ! nbtstat ! ipconfig The PowerVault 220S and the PowerVault 221S support up to 12 1-inch Ultra-3 SCSI hard-disk drives. ! False True On the PowerEdge 6600, what is the minimum number of power supplies required for the operating system to operate normally? ! Two Three One Four The processor VRMs on the PowerEdge 4600 are soldered to the system board. True !! False What is the maximum number of Xeon processors that a PowerEdge 2650 will support? Three The PowerEdge 2650 does not support Xeon processors. One ! Two What are the minimum and maximum amounts of memory that can be installed in a PowerEdge 400SC? 512 MB ? 2 GB 256 MB ? 4 GB ! 128 MB ? 4 GB 128 MB ? 2 GB If the power button is disabled in the PowerEdge 650 system setup, the system can be powered on but cannot be powered off using the power button. ! True False What feature allows clearing of the system password in the event the system password is forgotten or becomes corrupted on the PowerEdge 650? Pressing the power button three times Removing the coin battery on the systemboard !! The password jumper on the system board System security option in the system BIOS How many processors will the PowerEdge 1750 support? Three ! Two Four One Dell OpenManage Array Manager manages storage resources on remote stations with the following operating system: ? NT 4.0 Server Netware 5.0 Windows 98 ? Windows 2000 Advanced Server The SNMP community name cannot be specified during a Windows 2000 installation when using the Dell OpenManage Server Assistant CD. True ? False Which keys must be pressed to access the PERC 2, 2/Si, 3/Si or 3/Di BIOS configuration utility? ! Which of the following can be selected when installing Management Station Applications? !! Remote Management TCO Database Server !! Array Manager !! IT Assistant The PowerConnect 5224 has a red power LED illuminated when the internal power supply has failed. ! True False If a PowerConnect 5224 switch reports an 'Invalid IP address' while configuring the switch's IP address, you should: reboot the switch. replace the switch. update the firmware on the switch. ! use a different IP address. When replacing a power supply or an active cooling fan attached to the power supply on a PowerVault 220S or PowerVault 221S in a non-redundant configuration, you must _______ the enclosure before you begin. ! Power off Dissconnect Initialize Reboot On the PowerEdge 6600, you can only remove and replace one power supply at a time when the system is powered on. ? True False What option must be installed to support eight hard-disk drives internally on the PowerEdge 2600? 1 x 8 SCSI backplane ROMB hardware ? Peripheral bay backplane Split backplane card What is the maximum number of PCI cards that can be installed in a PowerEdge 400SC? Three ! Four Five Two The PowerEdge 650 has ________ DIMM sockets. Four ! Three Two One What is the minimum and maximum amount of memory that can be supported by the PowerEdge 650? 512 K/2 GB 256 MB/1 GB ! 128 MB/4 GB 1 GB/8 GB Multiple chioce: What is the purpose of expanding a virtual disk using Dell OpenManage Array Manager? To recover from a failed drive. !! To add a disk to an existing array. To decrease the size of an existing array. To change disk type. What must be specified when creating a virtual disk using Dell OpenManage Array Manager? Format type Set the permissions for the virtual disk to read only Disk name The virtual disk size The acronym RAID stands for: Reliable Array of Inexpensive Drives Redundant Array of Interconnected Disks Reliable Array of Inexpensive Disks !! Redundant Array of Independent Disks What is the default IP address of a PowerConnect 5212? 10.3.2.1 !! 0.0.0.0 10.1.1.1 192.16.0.1 What command saves the PowerConnect 5212 switch's running configuration to the startup configuration? copy start-cfg running-cfg move running-conf startup-conf !! copy running-config startup-config save running-cfg startup-cfg What is the maximum number of processor(s) that can be installed in a PowerEdge 400SC? Four ! One Two Three On the PowerEdge 650, the default position of the NVRAM_CLR jumper is set to enabled (jumpered). True !! False The PowerEdge 1750 has ________ embedded Broadcom NetXtreme Gigabit NICs. Zero One ! Two Three What two files can the customer upgrade without support intervention on a PowerConnect 5212? loader file !! config file !! opcode file diag file When the PowerVault 220S or PowerVault 221S is operating outside of its specified thermal range, the thermal LED will be: Blinking red Blinking amber Red in color ! Amber in color A PowerVault 220S or PowerVault 221S in a non-redundant configuration will have a _____ installed in the secondary EMM slot. RAID controller SCSI Terminator card ? Split-bus module Filler panel A blue blinking system status indicator on the PowerEdge 650 indicates? A fault with the hard-disk drive !! The system is identifying itself There is activity on the NIC The power is off What does a GATE A20 failure message indicate on the PowerEdge 650? Bad mouse cable Improperly installed memory module !! Faulty keyboard controller NVRAM_CLR jumper is installed On a PowerEdge 400SC, what is the possible problem when the rear panel LED indicators are lit as follows: A=Red, B=Green, C=Red, D=Red? Loose connection on your printer. !! PCI device configuration activity in progress or PCI device failure. Loose or improperly connected mouse. Ethernet cable connected in wrong port. With the PASSWD jumper installed on a PowerEdge 400SC, the password feature is disabled. !! False True What is the cause of a 3-4-2 beep code error that occurs during a PowerEdge 400SC system startup? Time of day-clock stopped DMA initialization failure System configuration check failure !! Screen-retrace test failure or test in progress The white RPS connector on the back of the PowerConnect 5224 is used for: ! connecting to a redundant power system. downloading firmware to the switch. managing the switch. cascading switches.